Tested by someone else
Analysis is performed by ILS Laboratories, an outside laboratory with no stake in the result. Their name, address and report number are printed on every certificate we publish.
Every lot we release carries a certificate of analysis from an independent laboratory, tied to that lot number and published on the product page before you order. The numbers below are the numbers on those certificates.
Most of this industry asks you to trust a number on a banner. We would rather hand you the document the number came from.
Analysis is performed by ILS Laboratories, an outside laboratory with no stake in the result. Their name, address and report number are printed on every certificate we publish.
A certificate belongs to a single lot number — QP-2608-009, not “BPC-157”. Lots differ, so a document that cannot be traced to the vial in your hand is a brochure, not a record.
Certificates are on the site, in full, as a PDF you can open without an account, an email address or a support ticket. Read them first and buy second — that is the intended order.
Each certificate states the method it used — purity, identity and quantitation by HPLC, endotoxin by USP <85>. We describe the tests that were run, not the tests that sound impressive.
Four steps, in this order. The last one is the one that matters: nothing is released ahead of its certificate.
Incoming material is assigned a Quill lot number in the form QP-YYMM-NNN. That number is what every later record is keyed to, from the certificate to the printed vial label.
A sample from the lot is submitted to ILS Laboratories for purity, identity and quantitation by HPLC, plus endotoxin by USP <85>. We do not produce the result we then publish.
The laboratory's report is posted whole — the PDF, not a summary of it — to a page anyone can open, alongside the product it belongs to.
Where a lot is still with the laboratory, the product page says so and the item cannot be bought. A pending result is worth stating plainly; it is not worth writing around.
A certificate of analysis is a set of specific measurements on a specific sample. Here is each line on ours, and what it does and does not establish.
The sample's chromatographic retention time is compared against a reference standard for the named compound. This is how the laboratory establishes that the material is what the label says.
The target peak as a share of total peak area at 214 nm. Across the lots published to date this figure runs 99.31% to 99.94% for the samples submitted.
How much of the vial's mass is peptide, as distinct from purity. The two are different measurements and the certificate keeps them apart — so we do too.
Bacterial endotoxin measured to the USP <85> compendial method, with the result stated in the report rather than summarised as a pass mark.
The report includes a fentanyl screen, returned as “Not Detected” at the assay's stated cutoff. Non-detection at a cutoff is a narrower statement than absence, and the certificate is where you can read which one you are getting.
The complete published record as it stands. Each row links to the laboratory's report for that lot — no account, no request form.
| Product | Lot | Tested | Purity (HPLC) | Laboratory | Certificate |
|---|---|---|---|---|---|
| QP-1S 10 mg | QP-2608-014 | 2026-08-25 | 99.94% | ILS Laboratories | View certificate |
| QP-3RT 10 mg | QP-2608-004 | 2026-08-25 | 99.93% | ILS Laboratories | View certificate |
| QP-3RT 15 mg | QP-2608-006 | 2026-08-25 | 99.93% | ILS Laboratories | View certificate |
| QP-2TZ 10 mg | QP-2608-002 | 2026-08-25 | 99.92% | ILS Laboratories | View certificate |
| QP-2TZ 20 mg | QP-2608-003 | 2026-08-25 | 99.90% | ILS Laboratories | View certificate |
| QP-3RT 30 mg | QP-2608-007 | 2026-08-25 | 99.90% | ILS Laboratories | View certificate |
| Melanotan II 10 mg | QP-2608-012 | 2026-08-25 | 99.84% | ILS Laboratories | View certificate |
| BPC-157 5 mg | QP-2608-008 | 2026-08-25 | 99.75% | ILS Laboratories | View certificate |
| BPC-157 / TB-500 blend 10 mg | QP-2608-011 | 2026-09-01 | 99.75% | ILS Laboratories | View certificate |
| BPC-157 / TB-500 blend 10 mg | QP-2609-001 | 2026-09-18 | 99.73% | ILS Laboratories | View certificate |
| NAD+ 500 mg | QP-2608-018 | 2026-09-18 | 99.66% | ILS Laboratories | View certificate |
| GHK-Cu 50 mg | QP-2608-013 | 2026-08-25 | 99.65% | ILS Laboratories | View certificate |
| TB-500 5 mg | QP-2609-006 | 2026-09-18 | 99.50% | ILS Laboratories | View certificate |
| QP-3RT 10 mg | QP-2609-007 | 2026-09-18 | 99.50% | ILS Laboratories | View certificate |
| TB-500 5 mg | QP-2608-010 | 2026-08-25 | 99.48% | ILS Laboratories | View certificate |
| BPC-157 10 mg | QP-2608-009 | 2026-08-25 | 99.39% | ILS Laboratories | View certificate |
| MOTS-C 10 mg | QP-2609-008 | 2026-09-18 | 99.39% | ILS Laboratories | View certificate |
| Glutathione 1500 mg | QP-2609-005 | 2026-09-22 | 99.37% | ILS Laboratories | View certificate |
| MOTS-C 40 mg | QP-2609-009 | 2026-09-18 | 99.31% | ILS Laboratories | View certificate |
| Bacteriostatic water 3 mL | QP-2608-001 | 2026-08-31 | — | ILS Laboratories | View certificate |
Purity figures are the reported HPLC results for the samples submitted from each lot. The full certificate index lives at quillpeptides.com/coa and is the authoritative version of this table.
If it isn't on a certificate, we don't claim it.
That rule is more restrictive than it sounds. It means we name the methods the laboratory actually ran instead of the ones that read well. It means a lot still in testing is described as still in testing. And it means the strongest thing we will say about a number is that you can go and read it yourself.
The certificates are open, the methods are named, and the catalogue is one click away.
Shop the catalogue